Changes between Version 10 and Version 11 of Procedures/NewSeason
- Timestamp:
- Apr 3, 2012, 5:36:53 PM (13 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Procedures/NewSeason
v10 v11 10 10 1. lever arm file 11 11 * ~arsf/usr/share/leverarm_values.csv 12 * Source: survey + ARSF-DAN calculation 12 * Source: survey + ARSF-DAN calculation (see below) 13 13 1. boresight file 14 14 * ~arsf/usr/share/boresight_values.csv 15 * [wiki:Processing/BoresightCalibration] 15 16 * Source: hyperspectral boresight flight + ARSF-DAN calculation 16 17 1. hyperspectral calibration files … … 19 20 * Source: Specim or FSF/ARSF radiometric + wavelength calibration 20 21 * Ensure these get sent to Phil at Ops 22 * Further ensure that the wls files on the instruments are updated and the old ones on the instruments destroyed beyond recovery. 21 23 1. hyperspectral sample scripts 22 24 * ~arsf/sample_scripts/YEAR … … 39 41 * update READMEs, etc 40 42 1. Create and update data quality report for new year 41 1. Create new data processing spreadsheet for new year42 * Copy last year's, clear data out and move it to appropriate location43 43 44 44 == Metadata == 45 45 46 46 1. Acquire application forms, store in ~arsf/arsf_data/YEAR/Applications 47 * Source: ARSF SC BSCW (http://bscw.badc.rl.ac.uk/bscw/bscw.cgi/0/68196 - ask Steve for access)47 * Source: ARSF SC - ask Steve for copies 48 48 1. Acquire alpha gradings, store on [wiki:Projects] pages 49 49 … … 57 57 * Hawk 58 58 * TABI, CASI or any other imaging instrument that is installed 59 * IMUs (Liteon and Honeywell) 59 60 60 61 In all cases, a measurement to a suitable reference point on the casing of the instrument, plus an engineering diagram of the instrument, is sufficient. We have these diagrams for the Specim and Leica instruments. … … 62 63 These values should be recorded at: 63 64 * [wiki:Processing/LeverArmOffset] 64 * ARSF DAN filesystem: 65 * ARSF DAN filesystem: ~arsf/usr/share/leverarm_values.csv 65 66 66 67 == Hyperspectral == … … 70 71 (explanation + insert link to boresight doc here) 71 72 72 Results should be recorded at [wiki:Processing/BoresightCalibration] and the73 Results should be recorded at [wiki:Processing/BoresightCalibration] and ~arsf/usr/share/boresight_values.csv 73 74 74 75 === Radiometric and spectral calibration === … … 76 77 There should have been one of these prior to the season starting. It must determine the spectral calibration of the instruments (what wavelength maps to what band) and the radiometric calibration (what gain to apply to map DN to radiance). 77 78 78 1. Ensure the wavelength files on the Specim are updated to the current season and the old ones are destroyed or moved off the system.79 1. Ensure the wavelength files on the Specim are updated to the current season and the old ones are destroyed. 79 80 80 81 == LIDAR ==