Changes between Version 9 and Version 10 of Processing/BoresightCalibration
- Timestamp:
- Nov 5, 2007, 1:00:48 PM (17 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Processing/BoresightCalibration
v9 v10 13 13 * All Eagle and Hawk numbers may have small errors due to timing problems on every flightline. The slippage caused by these errors may result in inaccurate placement of the markers used for boresight calibration. 14 14 15 No 2007 survey of the instrument positioning was done? David Davis said to use the 2006 numbers as the placement of the Applanix IMU and instruments was identical (seems unlikely?). These numbers derived from 2006 batch files .15 No 2007 survey of the instrument positioning was done? David Davis said to use the 2006 numbers as the placement of the Applanix IMU and instruments was identical (seems unlikely?). These numbers derived from 2006 batch files and taken from an email from AKW. 16 16 * ATM: 0.2655 0.006353 1.741 17 17 * CASI: 0.4732 0.007934 1.702