Changes between Version 19 and Version 20 of Processing/LidarCalibrationProcedure/problems


Ignore:
Timestamp:
Sep 5, 2014, 10:24:05 AM (10 years ago)
Author:
stgo
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • Processing/LidarCalibrationProcedure/problems

    v19 v20  
    99        * Further details (Calibration 2013)
    1010                * Autoboresight.exe is a program running within Attune. When autoboresight.exe crashes it doesn't necessarily crash Attune. In this case usually just autoboresight.exe crashed\\ and therefore wasn't creating an output. On the one occasion that autoboresight.exe was consistently working and a reasonable number of tie points were collected Attune \\ itself crashed. When the attune project was reloaded and autoboresight.exe was run again it would crash but attune would stay open.
     11
     12If attune throws an error saying that AutoBoresight.exe couldn't be found/won't work try running attune from the program files folder rather than a shortcut (C:/Program Files/Leica Geosystems/Attune/Attune.exe)
     13
     14Autoboresight begins to fail at reducing tie points sometimes, this appears to be at random. It's likely that attune will not be able to find any of the tie points you have made if this happens. The only fix seems to be to create a new project, add all your lines again (as the same line number/name!) then rename the old tie points file to the new project name convention and re-run. This does not work every time.
    1115       
    1216== lasground / ground_classify_las_bin.sh  ==