Version 9 (modified by edfi, 12 years ago) (diff) |
---|
LiDAR Calibration Notes - Software issues
Attune
- AutoBoreSight.exe error -"Boresight programme could not be found"
- Resolution: Check projection is correct (UTM or OSGB)
- Note: sometimes this doesn't fully resolve the issue, in which case currently no solution has been found.
- Resolution: Check projection is correct (UTM or OSGB)
lasground / ground_classify_las_bin.sh
- Failing on a section of line
- Resolution: Use a different line or manually classify that line.
ALSPP
- RangeCardCal Error
- Resolution: File missing from "Sent to" (C:\Documents and Settings\*user*\SendTo) folder.
- Alternatively use a different user's account that has already been set up.
- Resolution: File missing from "Sent to" (C:\Documents and Settings\*user*\SendTo) folder.
- Pulse Rate error when loading in raw LiDAR data - Doesn't appear to change the result, currently no solution
We are investigating the issues related to the software errors and have contacted the manufacturer
http://arsf-dan.nerc.ac.uk/trac/ticket/473 (Calibration Ticket)
Back to LiDAR Calibration Page here