Changes between Version 4 and Version 5 of Processing/POSPac


Ignore:
Timestamp:
Oct 15, 2021, 10:22:42 AM (3 years ago)
Author:
wja
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • Processing/POSPac

    v4 v5  
    4444  * Project > Find Base Stations > Select None > Tick all Precise Ephemeris and Broadcast Ephemeris rows, click "Download and Import" to download, then click "Download and Import" again to import.
    4545
    46 '''If four basestations are available:'''
     46'''Best method is 'IN-Fusion SmartBase:'''
    4747
     48Criteria:
     49  * At least four basestations
     50  * Precise ephemeris data
     51  * The flight is within the perimiter of these stations
     52  * The flight doesn't exceed 100km from a basestation
     53  * See POSPac manual Chapter 9 for more infomation
     54
     55Method:
    4856 * Project > SmartBase Quality Check
    4957 * If the quality is good, then it will prompt you to continue to the Applanix SmartBase (ASB) stage which will run when 'Continue' is clicked.
    5058
    51 '''For using a single basestation:'''
     59'''Otherwise try IN-Fusion Single Base:'''
     60
     61Criteria:
     62* Single basestation
     63* Basestation within 30km from start of flight
     64* Flight within 100km of basestation
    5265
    5366Note that multiple basestaions are not supported for RINEX version 3. For RINEX version 3, single base processing is required.