Changes between Version 9 and Version 10 of Processing/Py6S_vs_Hyperspectral
- Timestamp:
- Oct 21, 2015, 11:16:21 AM (9 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Processing/Py6S_vs_Hyperspectral
v9 v10 61 61 [[Image(f170021b_fenix_vs_sim_veg_spectra1.png, nolink, title="Py6S vs Fenix", margin=20, width=500px)]] 62 62 63 '''Figure above shows''' Fenix vs Py6S. Both spectra matches except for a Fenix spike close to 950 nm. No other spikes or depressions like which does not match the Py6S model should be found outside thatregion.63 '''Figure above shows''' Fenix vs Py6S. Both spectra matches except for a Fenix spike close to 950 nm. No other spikes or depressions like that one (which does not match the Py6S model) should be found outside the overlappiing region. 64 64 65 65 Moreover, peaks VNIR (around 750-850 nm) and SWIR (1000 nm) has to be present on the Fenix spectra. The SWIR peak should be lower than the VNIR but both of them should be comparable. You can find more detailed [wiki:Procedures/DeliveryChecking/ExampleFenixSpectra examples with pictures about erroneous spectra here].