Changes between Version 11 and Version 12 of Processing/RadiometricCalibration
- Timestamp:
- Dec 21, 2007, 2:45:08 PM (17 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Processing/RadiometricCalibration
v11 v12 9 9 }}} 10 10 11 Format appears to be 10 pairs of numbers (one each for channels 1-10). The second number in a pair looks like the sensor value at the lit level, not sure of the first number (calibrated light level? dark current value?). 11 Format is 10 pairs of numbers (one each for channels 1-10). The first number is the gain (multiplier), the second number is the dark current level. To compute a real world value, you should compute: 12 13 `real world value = (sensor_DN - dark_current_level) * multiplier` 12 14 13 15 == ATM calibration procedure == 14 16 15 (as described by Andrew Wilson and dodgily transcribed by Mike )17 (as described by Andrew Wilson and dodgily transcribed by Mike, then tested and annotated further) 16 18 17 19 1. The ATM is placed in the light bench kept at Kidlington.