Changes between Version 1 and Version 2 of Sensors/LeicaLIDAR/FWMikesNotes


Ignore:
Timestamp:
Jan 27, 2010, 3:26:50 PM (15 years ago)
Author:
mggr
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • Sensors/LeicaLIDAR/FWMikesNotes

    v1 v2  
    55The full waveform digitiser (FWD) is supplied as an upgrade to the existing ALS50v2 (and up) sensors, and essentially consists of an upgraded data logger and an intensity digitiser.  The discrete point recording subsystem is unchanged.  In implementation, the FWD is added as a spur from the main
    66{{{
    7                                                  --->  Full waveform digitiser   ---
    8  Laser receiver -> Automatic Gain Controller  --|                  ^                |-->  Data logger
    9                                                  --->  Discrete point subsystem  ---
     7                                                 +--->  Full waveform digitiser   -->--+
     8                                                 |                 ^                   |
     9 Laser receiver -> Automatic Gain Controller  -->|                 |                   |-->  Data logger
     10                                                 |                 |                   |
     11                                                 +--->  Discrete point subsystem  -->--+
    1012}}}
    1113