Version 16 (modified by edfi, 12 years ago) (diff) |
---|
LiDAR Calibration Notes - Known Software issues
Attune
- AutoBoreSight.exe error -"Boresight programme could not be found"
- Resolution: Check projection is correct (UTM or OSGB)
- Note: sometimes this doesn't fully resolve the issue, in which case currently no solution has been found.
- Resolution: Check projection is correct (UTM or OSGB)
- Further details (Calibration 2013)
- Autoboresight.exe is a program running within Attune. When autoboresight.exe crashes it doesn't necessarily crash Attune. In this case usually just autoboresight.exe crashed
and therefore wasn't creating an output. On the one occasion that autoboresight.exe was consistently working and a reasonable number of tie points were collected Attune
itself crashed. When the attune project was reloaded and autoboresight.exe was run again it would crash but attune would stay open.
- Autoboresight.exe is a program running within Attune. When autoboresight.exe crashes it doesn't necessarily crash Attune. In this case usually just autoboresight.exe crashed
lasground / ground_classify_las_bin.sh
- Failing on a section of line
- Resolution: Use a different line or manually classify that line.
ALSPP
- RangeCardCal Error
- Resolution: RangeCardCal File missing from "Sent to" (C:\Documents and Settings\*user*\SendTo) folder, this file can be copied and pasted from another person's SendTo folder.
- Alternatively use a different user's account that has already been set up.
- Resolution: RangeCardCal File missing from "Sent to" (C:\Documents and Settings\*user*\SendTo) folder, this file can be copied and pasted from another person's SendTo folder.
- Pulse Rate error when loading in raw LiDAR data - Doesn't appear to change the result, currently no solution
We are investigating the issues related to the software errors and have contacted the manufacturer
http://arsf-dan.nerc.ac.uk/trac/ticket/473 (Calibration Ticket)
Back to LiDAR Calibration Page here