#485 new flight processing

GB13/00, flight day 192/2013, Little Rissington

Reported by: mark1 Owned by: benj
Priority: immediate Milestone:
Component: Processing: general Keywords:
Cc: Other processors:

Description (last modified by tipo)

Data location: /users/rsg/arsf/arsf_data/2013/flight_data/arsf_internal/GB13_00-2013_192_Boresight

Data arrived from ARSF via network transfer on 15/07/2013

GB13/00 Scientific objective: ARSF internal boresight/calibration flight

GB13/00 Priority: urgent

PI: ARSF Internal

Sensors:

Camera (Not requested by PI)
Eagle (Requested)
Hawk (Requested)
LiDAR (Requested)

Change History (13)

comment:1 Changed 11 years ago by mark1

Base station ppp result using grafnav:
lat= 51 49 26.25264
lon= -1 17 18.72241
hei= 119.790

comment:2 Changed 11 years ago by mark1

Looks like first 3 flight lines have been reflown, so do not use these 3 for the calibration. Navigation processing is done, separation is quite bad (longitude ~ 0.4m) until ~402000s but then gets better. First 3 lines are before this time so another reason not to use them.

comment:3 Changed 11 years ago by edfi

RangeCardCal Output

A10B10
A20.013B2-0.002
A30.039B30.006
A40.010B40.023
Last edited 11 years ago by edfi (previous) (diff)

comment:4 Changed 11 years ago by edfi

Disregarding the first three flightlines as these were reflown

comment:5 Changed 11 years ago by edfi

Average Scanner Offset: -12479.91667

comment:6 Changed 11 years ago by edfi

RangeCardCal Output (after GCPs)

A12.91823B12.918
A22.932B22.916
A32.958B32.924
A42.929B42.942

comment:7 Changed 11 years ago by edfi

lascontrol.exe output

abs,rms,stddev
2.91823,2.91836 0.0276161

Version 0, edited 11 years ago by edfi (next)

comment:8 Changed 11 years ago by tipo

Hyperspectral boresight values:

Eagle 0.12 -0.35 0.5
Hawk 0.1 -0.85 0.5
Last edited 11 years ago by tipo (previous) (diff)

comment:9 Changed 11 years ago by edfi

LiDAR

Roll: -0.0009262

Pitch: -0.003236

Heading: 0.00027181

Last edited 11 years ago by edfi (previous) (diff)

comment:10 Changed 11 years ago by edfi

No FW data available

comment:11 Changed 11 years ago by edfi

LiDAR Calibration Reg file copied into Calibration folder

comment:12 Changed 11 years ago by tipo

  • Component changed from Processing: general to Archiving
  • Description modified (diff)
  • Owner set to benj

comment:13 Changed 11 years ago by tipo

  • Component changed from Archiving to Processing: general
  • Description modified (diff)